Wittmann Tempro Plus D 360 Manual !link! Jun 2026

The D 360 features a built-in level probe. If water drops below minimum, the controller closes the heater, opens the fill valve, and displays “Refill water – check leakage.”

Activate the internal automatic filling program via the controller. Wittmann Tempro Plus D 360 Manual

Cooling water IN ---> Y-strainer ---> Solenoid valve (PWM) -----+ | +---> EJECTOR NOZZLE | | Mold RETURN ---> Pt100 sensor ---> Pump ---> Heater tank ---> +---> MOLD FLOW | Fill/Drain port ---> Manual valve ---> Tank fill valve -------+ The D 360 features a built-in level probe

If you have any questions or need further assistance with your Wittmann Tempro Plus D 360, don't hesitate to contact the manufacturer or a authorized distributor. They can provide additional support and resources to help you get the most out of your temperature control unit. They can provide additional support and resources to

Turn off main power and check electrical contactors for pitting or thermal discoloration. Annual Descaling

is a versatile and robust controller. By following the operating procedures outlined in the official Wittmann manual, operators can maximize the service life of the unit and ensure superior mold temperature control.

Top